1.0
Automatic Insulation
Analyzer : (Capacitance and Tan
delta
test set) : |
|
|
The operation of Capacitance and Tan delta test set is fully controlled by
Laptop and
collects the test data, analyses the data, display the same in tabular and graphical format.
The test data for respective
HT capital equipments are stored for establishing the trend and accuracy + 0.25 % of the reading. 1.5 Calibration unit for validating accuracy at site. 1.6 Induction cancellation unit for energized switchyard operation.
1.7 0-12
kV AC, 300 mA. 1.9 Test set with Temperature and Humidity measurement facility. 1.10 In built charts for Tan delta value correction. |
![]() |
|
2.0 Tan
delta,
Dielectric Constant and Resistivity measurement test set with
|
|
| 2.1 Output with 0-500 V AC/DC output 2.2 Oil test cell as per BIS standards 2.3
Heater for Temp, up to 150
°C |
|
| 3.0 Partial Discharge Measurement Equipment : | |
|
3.1 The test Instrument detects Partial
Discharges in the high voltage insulation.
3.2
The Unit of measure is apparent charge pico coulomb
(pC) 3.3 The ndb make XDPIIB test instrument can be used : · To check the insulation quality of HT equipment at the time of manufacture. · To have the base foot print values before commissioning. · To check the discharge values during every maintenance cycle to check the ageing of the insulation. 3.4 Depending upon the measured values every six or twelve months to trend monitor the insulation. Detailed description of this test can be viewed at : |
|
|
4.0 Sweep Frequency Response Analyzer (SFRA) : For Transformer Core
and Make : Doble , Type : M5200 |
|
|
4.1 The best diagnostic instrument for detecting "hidden" transformer defects
4.2 The M5200 detects mechanical failure or movement of windings
due to short 4.3 The M5200 can "see" inside transformers and can detect
problems early,
4.4 The entire set is operated with a software which can be
used for analyzing |
![]() |
|
5.0 HV / MV Power Cables testing by : Very Low Frequency (VLF) test method
|
|
|
5.1 The new test method for
testing cables by AC sinusoidal waveform. 5.3 The VLF test set
detects ageing of the cable insulation, defects in insulation, 5.4 The test set can carry
out following tests :
·
Insulation Resistance measurement.
·
Polarization Index measurement.
·
Leakage current measurement.
·
Capacitance value measurement.
·
Tan delta value measurement.
·
DC (+ and - Polarity) HV testing.
·
To check the cable insulation
during manufacturing stage.
·
As a routine maintenance test to
check the insulation health. · To check the condition of joints.
5.6 The
detailed description of this test can be viewed at : |
![]() |
|
6.0 Lightning Arrester Test Set : For ON line health check up of Lightning Arresters |
|
|
6.1 Lightning arresters are tested online
6.2 Online testing of Lightning Arrester is carried out by harmonic
6.3 This test set has
an inbuilt voltage compensation circuit which is
|
![]() |
|
7.0 RSO Test Set : For main rotor winding Earth fault and Inter turn fault detection. The testing instrument used is, Rotor Reflectometer |
|
|
7.1 This is a world renowned, highly accurate Rotor Reflectometer for Recurrent Surge Oscillograph test.
7.4 Detailed description of this test can be viewed at
: |
![]() |
|
8.0 Digital Dual Channel Storage oscilloscope Make : This equipment is used in conjunction with RSO test instrument and partial discharge measurement for storage, transfer of measured wave form. |
|
|
9.0
Motorized digital megger having variable · Polarization Index measurement · Step Voltage Test · Dielectric Absorption Test · Dielectric Discharge Measurement · The Digital meggers are communicable with software for further analysis.
|
|
|
10.0 Winding Resistance Meter : |
|
|
This meter is designed on the principle of Kelvins bridge method.
It is used for measuring winding resistance of Alternators, Transformer, HT
motor,
10.1 Output : 1 Amp and 10 Amp DC 10.2 Range : 0 - 19.999 ohm 10.3 Accuracy : ± 0.1% of range
Special features of winding Resistance meter a. High stability, high voltage compliance and extremely low ripple source. b. Totally protected against inductive load and ranges c. Test current can be selected d. Suitable for live switchyard
e.
Fast and
stable readings for inductive loads
f. four wire
system of measurement
g. High resolution
i.
Works on 230V AC
mains |
![]() |